15–17 Nov 2023
東海村産業・情報プラザ「アイヴィル(iVil)」
Asia/Tokyo timezone

Session

Calculation of the Skyshine Radiation Measurement Experiment in Kansas by PHITS/PHITSによるカンザスでのスカイシャイン線測定試験の線量評価

17 Nov 2023, 14:20
東海村産業・情報プラザ「アイヴィル(iVil)」

東海村産業・情報プラザ「アイヴィル(iVil)」

東海村舟石川東三丁目1番1号

Conveners

Calculation of the Skyshine Radiation Measurement Experiment in Kansas by PHITS/PHITSによるカンザスでのスカイシャイン線測定試験の線量評価

  • Yusuke YASUNO (Mitsubishi Nuclear Fuel Co., Ltd.)

Presentation materials

There are no materials yet.

  1. Yusuke/裕介 Yasuno/安野 (Mitsubishi Nuclear Fuel Co., Ltd./三菱原子燃料株式会社)

    Kansas State University measured exposure dose from skyshine radiation using $^{60}$Co sources at Kansas in 1977 [1]. Mitsubishi Nuclear Fuel (MNF) performed calculation of this experiment with a three-dimensional Monte Carlo code PHITS v3.24 (Particle and Heavy Ion Transport code System), which is developed by JAEA [2].

    For nuclear facilities, it is necessary to calculate the exposure dose...

    Go to contribution page
Building timetable...